The HAM ThermoSensePT logs temperature from a PT100 or PT1000 resistance probe. It is for industrial applications that need accuracy and a wide temperature range.

The serial number starts with e51:.

Reading Unit Note
Temperature °C From the PT100 or PT1000 probe.
  • Industrial processes with PT100 or PT1000 probes.
  • Tanks, pipes and thermowells.
  • Temperature records for HACCP.

Connect the PT100 or PT1000 probe to the terminals of the device. Set in the settings if the probe has 2 or 3 wires. Put the probe at the point you want to monitor, for example in the thermowell.

You connect the device to WiFi from the mobile app. See Connect to WiFi.

For installation and availability, contact us.

  • 3-wire probe: turn it on for a 3-wire probe.
  • Res. at Ref. Temperature (R0): the resistance of the probe at 0 °C. It is 100 Ω for PT100 and 1000 Ω for PT1000.
  • Internal Ref. Res. (RR): the reference resistance of the measuring circuit. Change it only if we tell you to.
  • Calibration table (in Advanced): field correction, up to 6 points. It is not a laboratory certificate.
  • Alarm buzzer mode: the device makes a sound when an alarm is active. It is on by default.

The Recommended setups button on the device page suggests:

  • An alert when the temperature goes out of range.
  • An alert when the device stops sending data.

See Your first alert.

  • The temperature is off by a constant amount: check the R0 and 3-wire probe settings. They must match the probe.
  • For other problems, see wrong values and device offline.
Input PT100 or PT1000, 2 or 3 wires
Connectivity WiFi 2.4 GHz