Virtual devices
A virtual device is a device on the HAM platform without hardware. Its readings come from your own system through the API, not from a HAM sensor.
After that, the virtual device works like all other devices: charts, history, rules, reports and sharing.
When to use it
Section titled “When to use it”- You have a sensor or a system from a different manufacturer and you want its values in the HAM app.
- You want rules and notifications for values that your own software calculates.
Basics
Section titled “Basics”| Item | Value |
|---|---|
| Family | v (Virtual HAM). The serial number is, for example, v:123. |
| Readings | Up to 6, with the codes u0, u1, u2, u3, u4, u5 |
| Outputs | None |
| Keep-alive | None. The device changes only when you send values. |
The app has no screen to create a virtual device. For a new virtual device, contact support.
Send values
Section titled “Send values”Send a POST to virtual_device_update.php. You need admin permission on the device.
curl -X POST https://api.hamsystems.eu/virtual_device_update.php \ -H "Authorization: Bearer-API YOUR_API_KEY" \ -H "Content-Type: application/json" \ -d '{"serialno": "v:123", "R": {"u0": 2150, "u1": 48}}'| Field | Content |
|---|---|
serialno |
The serial number of the virtual device |
R |
The readings, keyed by code (u0 to u5) |
untime |
Optional. The time of the measurement in unix seconds. Without it, the server uses the current time. |
The server keeps only the fields serialno, R and untime. It ignores all other fields.
The response is JSON with messages and response.
| Error message | Cause |
|---|---|
Invalid arguments |
serialno is missing. |
Invalid login |
The key or the token is not correct. |
Access denied to device |
You do not have admin permission on the device. |
You read the values in the same ways as for all devices:
- REST API for the current state.
- Download historical data for the history.
- WebSocket for live changes.